SECOND STAGE VALVE
3755
When servicing the regulator
the following parts should be
replaced:
(see chapter servicekit)
Before assembly check
the following:
1. Diaphragm (1) and exhaust
valves (7). Check the sealing
surface to see if it is even and
uncracked.
2. Valve housing (4). Make sure
that the sealing surfaces are free
from defects and that the track
for the diaphragm is absolutely
clean.
3. The mouth-piece (10). Make
sure that there are no cracks.
4. Low pressure hose (15). Check
to make sure that the sealing
surface is undamaged, and that
the rubber does not show any
flaws.