JETSTREAM
1.0:E20
FIRST STAGE
2962, 3257, 3580, 3585
Removal:
1. Remove the protective cap (26).
2. Remove the locking screw (27)
with a 6 mm Allen wrench.
Remove the o-ring (28) and the
cupfilter (30).
3. Place the first stage in the
fixture. Remove the connecting
(3 1) with a 6 mm Allen wrench.
4. Remove the wheel (33) and the
oring (32) with an o-ring
remover. Make sure the sealing
surfaces are not damaged.
Sealing surfaces