1.0:E84
CYKLON
FIRST STAGE VALVE
3720
Secondary side:
1. Disconnect the low pressure
hose from the first stage valve
using a 13 mm box spanner.
2. Remove the o-ring (30) from the
low pressure hose with the o-
ring remover.
First stage valve with G 5/8āā:
3. Remove the locking screw (22)
with a 6 mm Allen wrench.
Remove the o-ring (24) and the
cup-filter (25) with o-ring (23).
First stage valve with Yoke:
3. Remove the knob (23) and the
protective cap (21). Remove the
locking screw (24) with a 6 mm
Allen wrench. Remove the cup
filter (26) and the o-ring (25).
4. Place the first stage valve with
the secondary side facing
upwards in the fixture.
30