CLEANING:
If corrosion or salt deposits occurs,
place all metal parts
concentrated Hempocid* or 15%
Hydrochloric acid for about 10
minutes.Then, rince the parts
thoroughly and blow dry with air.
The synthetic parts in the second
stage must not be treated with
solvent.They shall be cleaned in
freshwater only.
Checking:
Check the following parts very
carefully. Replace even if only
slightly damaged.
1. Valve needle (8). Check to make
sure that the needle is straight.
2. The blind screws (10 and 13).
Check to make sure the sealing
surfaces are undamaged. Also
check that the threads are not
damaged.
When servicing the regulator the
following parts should be replaced:
See chapter Servicekit.
1. All o-rings
2. Diaphragm
3. Cup filter
4. Valve seat
5. Washer

Table of Contents