CYKLON
1.0:E75
CLEANING:
If corrosion or salt deposits occurs,
place all metal parts – concentrated
Hempocid* or 15% Hydrochloric acid
for about 10 minutes. Then, rince the
parts thoroughly and blow dry with air.
The synthetic parts in the second stage
must not be treated with solvent. They
shall be cleaned in freshwater only.
*Hempocid = Acid Liquid Detergent
Containing phosphoric acid (5 - 10%)
and bactericid for desinfectant cleaning.
Checking:
Check the following parts very
carefully. Replace even if only slightly
damaged.
1. Valve needle (8). Check to make
sure that the needle is straight.
2. The blind screws (10 and 13).
Check to make sure the sealing
surfaces are undamaged. Also
check that the threads are not
damaged.
When servicing the regulator the
following parts should be replaced:
See chapter Service-kit.
1. All o-rings
2. Diaphragm
3. Cup filter
4. Valve seat
5. Washer