10 Operational Specifications
130
Revision 1.04
VPC3+S User Manual
Copyright © profichip GmbH, 2012
10.8 Processing Instructions
Generally, ESD protective measures must be maintained for all electronic
components. The VPC3+S is a cracking-endangered component that must
be handled properly.
Profichip products are tested and classified for moisture sensitivity
according to the procedures outlined by JEDEC. The VPC3+S is classified
as moisture sensitivity level (MSL) 3.
In order to minimize any potential risk caused by moisture trapped inside
non-hermetic packages it is a general recommendation to perform a drying
process before soldering.
10.9 Ordering Information
Version
Order Code
Package
Temperature Range
Notes
VPC3+S-BGA48
PALF2009
LFBGA48
Industrial
(-40°C to +85°C)
VPC3+S-QFP48
PALF2012
LQFP48
Industrial
(-40°C to +85°C)