10 Operational Specifications
118
Revision 1.04
VPC3+S User Manual
Copyright © profichip GmbH, 2012
10.6.4 Timing in the Synchronous Motorola Mode
If the CPU is clocked by the VPC3+S, the output clock pulse (CLKOUT 2/4)
must be 4 times larger than the E_Clock. That is, a clock pulse signal must
be present at the CLK input that is at least 10 times larger than the desired
system clock pulse (E_Clock). The Divider-Pin must be connected to ‘0’
(divider 4). This results in an E_Clock of 3 MHz.
The request for a read access to the VPC3+S is derived from the rising
edge of the E_Clock (in addition: XCS = 0, R_W = 1). The request for a
write access is derived from the falling edge of the E_Clock (in addition:
XCS = 0, R_W = 0).
AB10..0
DB7..0
R_W
valid
data valid
XCS
E_CLOCK
35
40
37
39
38
32
33
31
36
Figure 10-14: Synchronous Motorola-Mode, READ (AS = 1)