EasyManua.ls Logo

ProMinent Beta BT4a - 10 Troubleshooting; 11 Decommissioning, Dismantling and Disposal

ProMinent Beta BT4a
54 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
ProMinent
®
Page 29
10 Troubleshooting
CAUTION
•Wear protective goggles and clothing when working with hazardous chemicals!
Please observe the safety information sheets for dosing media!
Always de-pressurise the liquid end prior to working on a pump!
Pump is not priming even at full stroke length, and open bleed valve.
Reason Crystalline deposits on the ball seat because valve has dried out.
Remedy Detach suction tubing from chemical feed container and rinse liquid end thoroughly.
If this fails, dismantle valves and clean.
Green LED display (operating display) not lit
Reason Power supply not connected, or incorrect power supply.
Remedy Connect to correct power supply according to the details on the device label.
Reason Fuse is defective.
Remedy Contact your ProMinent branch or supplier!
Yellow LED display (warning indicator) is lit
Reason Liquid level in the feed tank has reached the first float-switch trigger level.
Remedy Refill chemical tank.
Red LED display (fault indicator) is lit
Reason Liquid level in the feed tank has reached the fault float-switch trigger level (20 mm from empty).
Remedy Refill chemical tank.
Red LED display (fault indicator) is flashing
Reason Pump operating mode is undefined.
Remedy Select the required operating mode.
Liquid is leaking from back plate
Reason There is a faulty seal between the liquid end and the diaphragm.
Remedy Tighten screws in the liquid end.
If this fails, replace diaphragm.
11 Decommissioning, Dismantling and Disposal
NOTE
When dismantling a pump, clean thoroughly, paying particular attention to the liquid end
in order to remove all traces of chemicals and dirt.
When disposing of a pump it must be broken down into separate material types. All
parts must be sent for recycling or for correct disposal according to current legal waste
disposal requirements.
Cleaned, chemical-free pumps may be returned to your ProMinent branch for disposal.