9 Installation, electrical
User qualification: Electrical technician - see
Ä ‘Qualification of personnel’
on page 12
WARNING!
Danger of electric shock
A mains voltage may exist inside the device.
Before any work, disconnect the device's mains
cable from the mains.
WARNING!
Risk of electric shock
This pump is supplied with a grounding conductor and a
grounding-type attachment plug.
To reduce the risk of electric shock, ensure that it is
connected only to a proper grounding-type recep‐
tacle.
WARNING!
Risk of electric shock
In the event of an electrical accident, the pump must be
quickly disconnected from the mains.
Install an emergency cut-off switch in the pump
power supply line or
Integrate the pump in the emergency cut-off man‐
agement of the system and inform personnel of the
isolating option.
WARNING!
Danger of electric shock
Incompletely installed electrical options can allow mois‐
ture into the inside of the housing.
Fit appropriate modules into the slot on the front of
the pump or use the original blank cover to seal it in
a leak-tight manner.
WARNING!
Danger of electric shock
A mains voltage may exist inside the pump housing.
If the pump housing has been damaged, you must
disconnect it from the mains immediately. It may
only be returned to service after an authorised
repair.
CAUTION!
Risk of short circuiting caused by moist pins
No moisture must reach the pins of the PROFIBUS
®
jack.
A suitable PROFIBUS
®
plug or protective cap must
be screwed onto the PROFIBUS
®
jack.
Installation, electrical
29

Table of Contents

Other manuals for ProMinent DULCO flex Control

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the ProMinent DULCO flex Control and is the answer not in the manual?

ProMinent DULCO flex Control Specifications

General IconGeneral
BrandProMinent
ModelDULCO flex Control
CategoryWater Pump
LanguageEnglish

Related product manuals