9.2.3.1 Suction lance with 2-stage level switch
Electrical interface
Data Value Unit
Voltage with open contacts 5 V
Input resistance 10 kΩ
Control via:
n potential-free contact (load: 0.5 mA at 5 V) or
n semiconductor switch (residual voltage < 0.7 V)
Pin Function 3-wire cable
1 Earth GND black
2 Minimum pre-warning blue
3 Minimum limit stop brown
9.2.3.2 Suction lance with continuous level measurement
Electrical interface
Pin Designation Function
1 5 V supply
Sensor + RX
5 V (4.85 V…5.25 V DC) feed to the
sensor and RX communication inter‐
face (viewed from sensor). Interrup‐
tion to the power supply for a commu‐
nication command max. 10 ms.
2 GND Reference potential
3 Sensor TX TX communication interface (viewed
from sensor)
The cable between the suction lance and pump is an adapter cable
- with 5 pins at the suction lance end and 3 pins at the pump end.
9.2.4
"Metering monitor" terminal
This terminal has no function in the DFXa.
9.2.5
"Hose rupture indicator" terminal
There is an option to connect a hose rupture indicator.
Plug cable from hose rupture indicator into “Hose rupture indicator" ter‐
minal.
3
21
P_BE_0016_SW
Fig. 14: Assignment on pump
3
12
P_BE_0017_SW
Fig. 15: Assignment on cable
3
21
P_BE_0016_SW
Fig. 16: Assignment on pump
1
4
2
3
P_DE_0010_SW
Fig. 17: Assignment on cable
Installation, electrical
34

Table of Contents

Other manuals for ProMinent DULCO flex Control

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the ProMinent DULCO flex Control and is the answer not in the manual?

ProMinent DULCO flex Control Specifications

General IconGeneral
BrandProMinent
ModelDULCO flex Control
CategoryWater Pump
LanguageEnglish

Related product manuals