15.2 Cleaning hose rupture indicator (option)
WARNING!
Warning of unnoticed escape of feed chemical
After the hose rupture indicator has been triggered, any
residue of feed chemical may affect its function.
– After the hose rupture indicator has been triggered,
clean and test it.
1. Unscrew the hose rupture indicator using an SW 14 open-ended
spanner.
2. Clean the hose rupture indicator with a suitable liquid - if possible
using water.
3. Test the connected hose rupture indicator: fully immerse the
tapered section at the front in water.
ð
The continuous display indicates a hose rupture.
4. Thoroughly dry the hose rupture indicator.
ð
The continuous display no longer indicates a hose rupture.
5. Screw the clean and dry hose rupture indicator into the hole until
hand-tight and liquid-tight.
Repair
88