EasyManua.ls Logo

ProMinent DULCO flex Control - 18 Technical Data; Performance Data; Precision; Viscosity

ProMinent DULCO flex Control
120 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
18 Technical data
18.1
Performance data
Liquid end
type
Minimum capacity
at maximum back
pressure
Speed, max. Connector
size
Outside Æ x
inside Æ
Suction lift* =
priming lift
Permissible
priming pres‐
sure on suc‐
tion side
Weight
bar l/h rpm mm m water
column
bar kg
0730 7 * 30 ** 100 12x9 9 1 5.8
0530 5 * 30 ** 100 12x9 9 1 5.8
Data calculated with water at 20°C.
* - Depending on hose material
** - Minimum capacity: 10 ml / h
18.2 Precision
Parameter Value
Capacity range of the product range -5 ... + 5 %
Reproducibility ± 2 % *
* with pump hose drawn in (after approx. 200 revolutions)
18.3
Viscosity
The liquid ends are suitable for the following viscosity ranges:
Design Range Unit
Standard 0.7 ... 10,000 mPas
DULCO flex Control at 100 rpm