18 Technical data
18.1
Performance data
Liquid end
type
Minimum capacity
at maximum back
pressure
Speed, max. Connector
size
Outside Æ x
inside Æ
Suction lift* =
priming lift
Permissible
priming pres‐
sure on suc‐
tion side
Weight
bar l/h rpm mm m water
column
bar kg
0730 7 * 30 ** 100 12x9 9 1 5.8
0530 5 * 30 ** 100 12x9 9 1 5.8
Data calculated with water at 20°C.
* - Depending on hose material
** - Minimum capacity: 10 ml / h
18.2 Precision
Parameter Value
Capacity range of the product range -5 ... + 5 %
Reproducibility ± 2 % *
* with pump hose drawn in (after approx. 200 revolutions)
18.3
Viscosity
The liquid ends are suitable for the following viscosity ranges:
Design Range Unit
Standard 0.7 ... 10,000 mPas
DULCO flex Control at 100 rpm