EasyManua.ls Logo

Promise Technology Pegasus32 R6 - Stripe Size

Promise Technology Pegasus32 R6
267 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
216
Promise Technology
Pegasus32 R4/R6/R8
RAID 60 – Double Parity + Stripe
The PROMISE RAID 60 combines RAID 6 distributed (double) parity and RAID 0 block-level striping.
RAID 60 can increase performance by reading and writing data in parallel or striping, while
simultaneously providing parity.
PROMISE implements RAID 60 by creating a data stripe across two RAID 6 sets. This creates very
high fault tolerance, two drives in each RAID 6 set can fail without interrupting I/O or loss of data.
A minimum of eight drives are required for a RAID 60, so this option is available on the R8.
PROMISE RAID 60 starts with RAID 6 double parity, then stripes the blocks
RAID60isavailableontheR8.Togureoutthecapacity,multiplythesmallestdrivecapacitybyfour.
So an R8 with 8 2 TB drives has a capacity of 8 TB with a RAID 60.
Advantages Disadvantages
• High Read data transaction rate
• Medium Write data transaction rate
• Good aggregate transfer rate
• Safest RAID level
• High disk overhead
(four drives as hot spares on R8)
• Slightly lower performance than RAID 50
Recommended Applications for RAID 60 include applications that require extremely high fault
tolerance and good I/O performance.

Table of Contents