125
Managing the Pegasus32Pegasus32 Product Manual
Creating a Disk Array Manually
This feature creates a disk array only. You can also use the Wizard to create a disk array with logical
drives and spare drives at the same time.
To create a disk array:
1. From the Dashboard menu, click the Disk Array link.
2. Click the Create Disk Array button.
3. Accept the defaults or make changes:
• Enter an alias in the Alias eld
Maximum of 32 characters; letters, numbers, space between characters, and underscore.
• Enable Media Patrol – Uncheck to disable on this array.
For more information, see “Media Patrol” on page 99.
• Enable PDM – Uncheck to disable on this array.
For more information, see “PDM” on page 106.
!
WARNING
If you are using utility to create or delete a disk array or logical drive, the
system will reboot if Pegasus32 is running USB mode. It is important to make
sure the Pegasus32 not being accessed (no IO operation in progress) before
submitting the request.