Running Redundancy Check (CLU)
Redundancy Check is a maintenance procedure for logical drives in fault-tolerant disk arrays that
ensures all the data matches exactly.
To run Redundancy Check:
1. Main Menu >> Logical Drive Management
2. Highlight the logical drive you want and press Enter.
3. Highlight Background Activities >> Start Redundancy Check
The redundancy check parameters appear.
• Auto Fix–Correctsinconsistenciesautomatically
• Pause On Error–PausestheRedundancyCheckwhenanerrorisfound
To change a parameter, highlight it and press the backspace toggle between Yes and No.
4. Highlight Start and press Enter.
If necessary, you can pause and resume or stop and restart the Redundancy Check. You can
use the logical drive while Redundancy Check is running.
For Redundancy Check rate, see “Making Background Activity Settings (CLU)” on page 141.
139
Managing with CLUVess A6120 Product Manual