Managing with CLIVess A6120 Product Manual
factorydefaults
Usage
factorydefaults -a <action> -t <type>
Summary
The factorydefaults command restores factory default settings.
Options
-a <action> Species the action to perform.
restore Restore the factory default settings.
-t <type> Species the type of settings to restore.
all All settings.
allfw All rmware settings.
allsw Subsystems only. All software settings.
Following are individual Firmware settings:
bga Background activity settings.
ctrl Controller settings.
encl Enclosure settings, including temperature thresholds.
netiscsi Subsystems only. Network settings of iSCSI ports.
netmgmt Subsystems only. Network settings of management ports.
phydrv Physical drive settings.
subsys Subsystem settings.