179
Managing with CLIVess A6120 Product Manual
Examples
event
event -v
event -l nvram
event -a clear -lnvram
event -c 200
event -a list -i852 -c200
Options
-a <action> Species the action to perform.
list (Default) Displays information and status of the enclosure.
mod Modies settings. Requires the -s option.
-e <encl id> Enclosure ID. The default value is 1 if unspecied.
For list action, the default is for all enclosures if unspecied.
-s “<option>=<value>” Species the settings to change. Applies to the JBOD enclosures only.
tempwarning= (25-45) Enclosure warning theshold temperature, in degrees Celsius.
tempcritical= (30-51) Enclosure critical theshold temperature, in degrees Celsius.
ctrltempwarning= (90-95) Controller warning theshold temperature, in degrees Celsius.
ctrltempcritical= (100-105) Controller critical threshold temperature, in degrees Celsius.
-t <FRU type> Species which type of FRU to locate. Requires -a locate option.
ctrl Locates the controller.
cooling Locates the cooling unit.