Configuration MP.11-R Installation and Management
System Parameters
63
Notes:
One of the most important details to pay attention to in Routing mode are the unit’s and the PC’s default gateways. It
is a common mistake to set up the PC’s gateway to point to the SU when the SU is in Bridge mode and the BSU is in
Routing mode. Always check to make sure the PCs on your network are configured to send their IP traffic to the
correct default gateway.
Be sure to reboot the unit to permanently save static routes. New routes take effect immediately without a reboot, but
are not permanently saved with your configuration until you do reboot the device. An unexpected power outage could
cause static routes you entered to “disappear” when the unit reboots if they have not been saved. You also should
save a copy of your unit’s configuration file in case the unit must be reloaded. This saves you from being required to
re-enter numerous static routes in a large network.
The routing table supports up to 500 static routes.