Q24/Q48 Tape Library Installation and Operations Manual
Error
Code
Description
User Action
Critical Component Status
89
Gripper blocked
Run ‘Library Verify Test’,
after several occurrences
contact technical support
Media changer probably defective.
Gripper motor not connected or defect.
Gripper motor voltage to low.
Media changer controller or distribution
boards defect.
Check gripper mechanism according
stiffness in movement.
8A
Slider blocked
Run ‘Library Verify Test’,
after several occurrences
contact technical support
Media changer probably defective.
Slider Motor not connected or defect.
Slider motor voltage to low.
Media changer controller or distribution
boards defect.
Check slider mechanism according
stiffness in movement.
8B
Elevator blocked
Run ‘Library Verify Test’,
after several occurrences
contact technical support
Media changer probably defective.
Elevator motor not connected or defect.
Elevator motor voltage to low.
Media changer controller or distribution
boards defect.
Check elevator mechanism according
stiffness in movement
8C
Rotation blocked
Run ‘Library Verify Test’,
after several occurrences
contact technical support
Media changer probably defective.
Rotation motor not connected or defect.
Rotation motor voltage to low.
Rotation home sensor defect.
Rotation sensor connecting cable
damaged.
Media changer controller or distribution
boards defect.
8D
Sled blocked
Run ‘Library Verify Test’,
after several occurrences
contact technical support
Media changer probably defective.
Sled motor not connected or defect.
Sled motor voltage to low.
Sled home sensor defect.
Sled sensor connecting cable damaged.
Media changer controller or distribution
boards defect.
Check sled mechanism (guide rail,
ducktail) according stiffness in
movement.
8E
Cannot find gripper
block within the
expected range
Run ‘Library Verify Test’,
after several occurrences
contact technical support
Media changer probably defective.
Elevator distribution board defect.
Cabling incorrect.
Check gripper gears.
© Copyright QUALSTAR 2015 75