Appendix C SFC6400A/SFC1450A Synthesized Frequency Upconverter
C-6 TM106 Rev. 1.1
STATUS current
DESCRIPTION
"A bit field. On startup, the agent initializes this
to the value '00000000'B.
Bit 0 = LO Fault
Bit 1 = Signal Fault
Bit 2-7 = Spares
0 = Pass, 1 = Fail"
::= { radConverterStatus 11 }
radConverterLatchedMinorAlarmStatus OBJECT-TYPE
SYNTAX AlarmByteType
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"A bit field. On startup, the agent initializes this to
the value '00000000'B.
Bit 0 = RF Dtect Fault
Bit 1 = IF Dtect Fault
Bit 2-7 = Spares
0 = Pass, 1 = Fail"
::= { radConverterStatus 12 }
radConverterICCAddress OBJECT-TYPE
SYNTAX INTEGER (1..255)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
" "
::= { radConverterStatus 13 }
radConverterICCType OBJECT-TYPE
SYNTAX INTEGER (0..255)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"A bit field that shows converter ICC type. On startup, the agent
initializes this to the value '00000000'B.
Bit 0-3 = Band
Down-Band: 0 through 5
0=Normal C-Band, 1=Extended C-Band, 2=Normal Ku-Band,
3=Normal American Ku-Band, 4=India High C-Band,
5=European Ku-Band
Up-Band: 0 through 4
0=Normal C-Band, 1=Extended C-Band, 2=Normal Ku-Band,
3=Normal Ku-Band, 4=India High C-Band
Bit 4-5 = Spare Not Used
Bit 6 = Normal_Custom 0=Normal, 1=Custom
Bit 7 = Down_Up 0=Down, 1=Up"
::= { radConverterStatus 14 }
-- --------------------------------------------------------------------------------------------------------------------
-- --------------------------------------------------------------------------------------------------------------------
-- Converter Switch non-volatile status information.
radConverterSwitchBackupMode OBJECT-TYPE
SYNTAX INTEGER {
manual(1),
auto_nonrevertive(2),
auto_revertive(3)