SFC6400A/SFC1450A Synthesized Frequency Upconverter Appendix C
TM106 – Rev. 1.1 C-7
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Selects MANUAL or AUTOMATIC backup modes.
Manual: A Prime Converter can be backed up through manual control only.
Auto-Nonrevertive: A Prime Converter will be backed up if it fails.
It will remain backed up until it is manually unbacked.
Auto-Revertive: A Prime Converter will be backed up if it fails.
If a second Converter of a higher priority (see 7. below) fails, the
Switch will unback the first and backup the second Converter. Also,
if the first Converter recovers after it has been backed up (i.e., no
longer has a fault), the Switch will unback it and place it online again."
::= { radConverterSwitchNVStatus 1 }
radConverterSwitchLearn OBJECT-TYPE
SYNTAX PrimeControlType
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Learn Prime converter or learn All. Causes the Backup unit to 'Learn'
all the settings of the selected Primes. The Backup can only backup a
Prime that it has learned."
::= { radConverterSwitchNVStatus 2 }
radConverterSwitchBackupTest OBJECT-TYPE
SYNTAX PrimeControlType
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Checks if Prime can be backed up."
::= { radConverterSwitchNVStatus 3 }
radConverterSwitchForceBackup OBJECT-TYPE
SYNTAX INTEGER (0..8)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Force a manual backup (select 1..8), or unback of a Prime (select 0).
When in Manual Backup Mode, this selection will force the selected Prime
to be backed up. Unback will release any Prime that is currently backed
up."
::= { radConverterSwitchNVStatus 4 }
radConverterSwitchPriority OBJECT-TYPE
SYNTAX INTEGER (0..8)
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"Prime converter priority. Sets the switching priority of a Prime unit.
If more than one unit fails at the same time, the higher priority unit
will be backed up. Also, if one unit is currently backed up and a second
unit with a higher priority fails, the first unit w ill be unbacked and
the second unit will be backed up (but only if Backup Mode is
Auto-Revertive, see 1. above). The priority is set as follows.
0 = No priority (the Switch will ignore the Downconverter).
1 = Highest priority.
8 = Lowest priority."
::= { radConverterSwitchNVStatus 5 }