EasyManua.ls Logo

Raisecom RC953-GESTM1 - 24.1 Clock Mode Command (E1)

Raisecom RC953-GESTM1
197 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
www.raisecom.com User Manual
141
Chapter 24 The configuration command under e1Interface configuration
mode of remote RC953-FX8E1.
24.1 clock-mode
[Command Format]
clock-mode {master|slave}
[Function]
Set E1 clock mode.
[Default]
master
[Command mode]
Interface configuration mode.
[Application Example]
RC953-GESTM1#
config
RC953-GESTM1(config)#
remote ric 1
RC953-GESTM1(config-RC953FX8E1/1)#
interface e1
RC953-GESTM1(config-RC953FX8E1/1-e1/1)#
clock-mode slave
Set successfully.
24.2 crc-auto
[Command Format]
crc-auto {enable|disable}
[Function]
Crc is enable of disable of framed e1.
[Default]
disable
[Command mode]
Interface configuration mode.
[Instructions]
It is disable under clarity mode.
[Application Example]
RC953-GESTM1
# config

Table of Contents