www.raisecom.com User Manual
69
RC953-GESTM1(config)# interface sdh 1
RC953-GESTM1(config-sdh/1)# sdh aupje -threshold positive 10000
Set successfully
8.5 sdh force-switch
[Command Format]
sdh force-switch (work-line|protection-line|clear) timeslot [TSSTRING]
[Function]
Configure force-switch.
[Parameter]
(work-line|protection-line|clear): {work-line|protection-line|clear} {timeslot TSSTRING|}
TSSTRING: Switch to caracter line.
[Default]
N/A
[Command mode]
Global configuration mode
[Instructions]
If there is no TSSTRING.
[Command Execute Echo]
N/A
[Application Example]
RC953-GESTM1(config)# sdh force-switch work-line timeslot
Set successfully
8.6 sdh exc-threshold
[Command Format]
sdh exc-threshold {section|line|higher-path|lower-path} <3-5>
[Function]
Set SDH excessive threshold
[Parameter]
{section|line|higher-path|lower-path}: Set excessive threshold line.
section: regeneration segment
line: multiplex segment5
high-path: higher order path
low-path: lower order path