Chapter 7 Alarming management command of RC953-GESTM1
7.1 alarm-trap-disable
[Command Format]
alarm-trap-disable (ric|rmc|system|innere1|ge)
no alarm-trap-disable (ric|rmc|system|innere1|ge)
[Function]
Config alarm-trap-disable, use no command to delete alarm-trap-disable.
[Parameter]
(ric|rmc|system|innere1|ge): Choose alarm-trap-disable mode.
[Default]
N/A
[Command mode]
Global configuration mode
[Command Execute Echo]
Set successfully !
Information showed when alarm-trap-disable is set successfully.
[Application Example]
RC953-GESTM1(config)# alarm-trap-disable ge
Set successfully!
[Relevant Commands]
Command Description
alarm-trap-disable index ALARMNO
Shielding alarm-trap-disable.
alarm-trap-disable sdh (section|line|path|tu|vc)
Shielding alarm-trap-disable of SDH.
7.2 alarm-trap-disable index
[Command Format]
alarm-trap-disable index ALARMNO
no alarm-trap-disable index ALARMNO
[Function]
Shielding the alarm information, use no command to cancel alarm-trap-disable.

Table of Contents