www.raisecom.com User Manual
71
8.8 sdh overhead c2
[Command Format]
sdh overhead c2 expected BYTE transmit BYTE
[Function]
Set the C2 byte content.
[Parameter]
BYTE: The first parameter express the C2 content that expect to receive, it is hexadecimal.
BYTE: The second parameter express the C2 content that expect to receive, it is hexadecimal.
[Default]
Default is 0x02.
[Command mode]
Interface configuration mode.
[Application Example]
RC953-GESTM1# config
RC953-GESTM1(config)# interface sdh 1
RC953-GESTM1(config-sdh/1)# sdh overhead c2 expected 0x13 transmit 0x13
Set sdh C2 expect byte successfully!
Set sdh C2 transmit byte successfully!
8.9 sdh overhead j0
[Command Format]
sdh overhead j0 expected MSG transmit MSG
[Function]
Set regenerator section trace J0, use no command to disable J0.
[Parameter]
MSG: msg required message
MSG: msg transmitting message
[Default]
Raisecom-Opcom
[Command mode]
Interface configuration mode.
[Application Example]
RC953-GESTM1# config
RC953-GESTM1(config)# interface sdh 1