2.3 Safety symbols on the device
Table 2: Symbols on the device
The patient connections P1/T1, P2/T2 and pO
2
are Type CF ones and are classified as
having defibrillation protection.
Note: Please observe the instruction manual or important safety-related information.
For the patient connections, the sign means that only accessory parts approved by the
manufacturer may be connected to the NeuroSmart, because protection of the medical
device against the consequences of a defibrillator’s discharge depends on the use of suit-
able cables.
Inputs and outputs, digital and analogue
Follow the instruction manual
Observe disposal regulations. Do not throw used devices away in landfill waste.
Observe ESD protection measures
It is recommended that the operator instructs all employees involved in using the device
about ESD measures. Training should include:
Contact pins of plugs/sockets, which are provided with an ESD warning label, must not be
touched. Connections between these plugs must not be made without using ESD protec-
tion measures. In particular, the causing of high electrostatic discharges at the labelled
points must be avoided. This is supported through the use of appropriate ESD work cloth-
ing, an appropriate ESD working environment (ESD floors) and ESD packaging.
Device meets the basic requirements of Directives 93/42/EEC and 90/385/EEC