CHAPTER 4
30 RCM - Sprayer and AIM Command FLEX™ II Calibration and Operation Manual
FLOW METER CALIBRATION
Enter the calibration value for the flow meter used to monitor the flow of product to boom sections.
The flow meter calibration value and units are typically found on a tag or label affixed to the flow meter.
NOTE: Be sure to select the appropriate units for the flow meter calibration to ensure proper calibration of
the application system.
FLOW METER PULSE/UNITS
Select the units for the flow meter from this drop-down list. The pulses/units is the number of pulses that the flow
meter will generate for a given amount of product measured by the flow meter.
For example, a flow meter calibration value of 710 and a Pulse/Units value of 10 L indicates that 10 liters of product
is measured through the flow meter for every 710 pulses of the flow meter.
NOTE: Raven flow meters use a meter cal in pulses per 10 gallons [37.9 L]. Other manufacturers may use
different meter cal units.
FLOW METER LOW LIMIT
The minimum flow rate which the flow meter can read accurately. When the flow rate is below this setting, the flow
will be calculated based off the pressure and tip size.
NOTE: Refer to the flow meter manufacturer’s specifications when setting the low limit. Flow limits for Raven
RFM flow meters can be found in “Rate Sensor Setup” on page 29.
TANK FILL FLOW METER CALIBRATION
NOTE: The optional tank fill system is not required for AIM Commend Flex™ 2 operation and may not be
installed on all equipment with these application control systems.
The fill system flow meter calibration value and units may be found on the tag attached to the flow meter installed
in the fill system plumbing.
NOTE: Be sure to select the appropriate units for the flow meter calibration to ensure proper calibration of
the tank fill system.
TANK FILL FLOW METER PULSE/UNITS
NOTE: This feature is not available with injection product control channels.
Select the units for the flow meter from this drop-down list. The pulses/units is the number of pulses which the
flow meter will generate for a given amount of product measured by the flow meter. The fill meter calibration, or
meter cal, value and units may be found on the tag attached to the flow meter installed in the tank fill system.
For example, a flow meter calibration value of 710 and a Pulse/Units value of 10 L indicates that 10 liters of product
is measured through the flow meter for every 710 pulses of the flow meter. Be sure to select the appropriate units
for the flow meter calibration to ensure proper calibration of the tank fill system.
NOTE: Raven flow meters use a meter cal in pulses per 10 gallons [37.9 L].
Copy the information from the tag for future reference as tags may fade or be lost during operation.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Raven Command FLEX II and is the answer not in the manual?

Raven Command FLEX II Specifications

General IconGeneral
BrandRaven
ModelCommand FLEX II
CategoryPaint Sprayer
LanguageEnglish

Related product manuals