CHAPTER 8
80 RCM - Sprayer and AIM Command FLEX™ II Calibration and Operation Manual
Notification
Off pressure low
Check for low tank level.
Check for correct target pressure.
Check for electric or manual valves and sump
are opening correctly.
Check strainers and check valves for
obstructions.
Check for damaged pressure sensor or
cabling.
Check for correct tip size.
•Check for system leak.
Check pump for proper operation.
Check Off Pressure Alarm % value.
Off rate high
Increase operation speed.
Check for correct target rate.
Check NCV efficiency number. - Should be
between 90 and 105.
Check for correct tip size for desired rate,
speed, and pressure.
Check flowmeter calibration value. - May be
too low.
Check poppets for excessive wear.
•Check for leaks.
Turn on more sections.
Check Off Rate Alarm % value.
Off rate low
Decrease operation speed.
Check for correct target rate.
Check NCV efficiency number. - Should be
between 90 and 105.
Check for correct tip size for desired rate,
speed, and pressure.
Check flowmeter calibration value. - May be
too high.
Check poppets for obstructions.
Ensure all boom valves or electronic valves
and sump are opening correctly.
Check strainer for plugging.
Check for pinched hoses.
Turn off more sections.
Check Off Rate Alarm % value.
Type Description Recommended Actions