E-4 HSB Series Color LCD Display
Appendix E:
Connecting A
Raytheon ST80
ST80 System (without Course Computer)
If you have a Raytheon ST80 system and a Raytheon active compass we
recommend that you configure your system as follows:
Ensure the active compass is re-wired to provide heading data on NMEA.
Provide 12V power to the active compass.
Connect the active compass to NMEA input of the display.
If you require heading data on the SeaTalk system when the 10.4" LCD/
10" CRT display is switched OFF, you must fit a NMEA/SeaTalk interface
box (part number Z290 or E85001). The NMEA heading data is connected
to the interface box (in addition to the 10.4" LCD/10" CRT display).
Set Bridge NMEA Heading OFF in the display System Set Up menu.
If you do not fit a NMEA/SeaTalk interface box, set Bridge NMEA Head-
ing ON in the display System Set Up menu.
The 10.4" LCD/10" CRT display provides the heading data to the SeaTalk
system. Note that when the display is switched OFF, heading data is not
available on the SeaTalk system.
Manually calibrate the compass in NMEA mode as described in the section
Calibrating the ST80 Active Compass.