Menu item and description Options
Color threshold
Color threshold determines the signal strength below which
target returns are not shown.
A low value results in only the strongest colors or lightest
shades being displayed.
V
alue between 0% to
100%.(100% (default))
Scroll speed
Determines the scrolling speed for the Sonar image.
Value between 0% to 500%
(100% (default)).
Transducer tab
Menu item and description Options
Transducer:
Displays the type of connected transducer.
N/A
Display depth as:
Determines the position from where depth readings are taken.
• Below keel
• Below waterline
• Below transducer (default)
HV transducer alignment:
You can select which orientation your HyperVision™ transducer
has been installed in. E.g.: if you have installed the transducer
on a trolling motor, the transducer may have been installed with
the bow arrow pointing towards the stern of the trolling motor
instead of the bow.
Forwards should be selected if the transducer’s bow arrow
is pointing towards the bow.
Backwards should be selected if the transducer’s bow arrow
is pointing towards the stern.
• Forwards (default)
• Backwards
Enable temperature sensor:
Enables and disables the selected transducer’s temperature
sensor.
• On
• Off
Current temperature:
Displays the transducer’s current temperature reading.
N/A
Calibrate temp
Allows you to enter an offset between the actual measured
water temperature and the current temperature displayed by
your transducer
.
Offset temperature value.
Sounder tab
Menu item and description Options
Ping enable:
Enables and disables transducer ping.
• On (default)
• Off
Ping rate limit:
Allows you to restrict the transducer’s maximum ping rate to
suit current conditions.
Value between 1 and 100
(80 (default).
Interference rejection
Removes interference caused by other transducers on your
vessel or from vessels equipped with transducers close by.
• Auto (default)
• Low
• Medium
• High
• Off
114