Installation plan for arm systems
8
102-127108955 V1.1 27/ 102
Installation plan for arm systems
Standard arm (pushing)
Standard arm Lintel dimension X Article number
(Dimensions in mm)
SG 1 0…120 102-127808184
SG 2 100…220 102-127808215
SG 3 210…330 102-127808216
Installation of operator on door leaf
IMPORTANT
Consult the assembly dimension diagrams in chapter Assembly dimensions dia-
grams.
CAUTION
The connecting bolt can fall out if mounted incorrectly.
• Incomplete door movements or bruises because of falling pieces.
The connecting bolt has to be installed from top to bottom and needs to be
secured with a locking washer.
Installation on door frame Installation on door leaf
8
8.1
8.1.1