Operating instructions DFA 127
14
102-127108955 V1.1 57/ 102
Locked
The locking is activated in the Locked operation mode.
Table of signals (X marks a release reaction)
CLOSED OPENING OPEN CLOSING
AKI X X X
AKA X X X
SSK X X X X
SIO X X X
SIS X X
TIPP
OFF
This operation mode can be used only in the USA. The operator is switched to manual op-
eration (without configurations). An SSK opening is possible, but only under surveillance be-
cause some monitoring functions are disabled. Functions like parameter settings, Flash-
update, continue to work.
CLOSED OPENING OPEN CLOSING
AKI
AKA
SSK X X X X
SIO
SIS
TIPP
BODYG X X
RAILB X X
RESET (hidden button between the buttons and )
After pressing the button for approx. 5 seconds, this status message appears on the
display:
Press on the button