Configurations
16
102-127108955 V1.1 79/ 102
→ SAMP Signal for connecting an optical and/or acoustic indicator in an
interlock control.
▪ This signal shows that an opening command is regis-
tered, but cannot yet be carried out, because the in-
terlock is occupied from the opposite door.
→ SAA Output signal for synchronisation of an interlock.
▪ With the signal
Block triggering
the other door is noti-
fied that the interlock is currently occupied.
→ SFS_OUT Output interlock sequential control.
▪ Appropriate for interlocks and draught lobbies without
triggering sensors within the interlock chamber.
▪ The signal must be linked with the input signal
SFS_IN of the other door. Thus, the triggering signal
is transmitted to the first door.
MISCELLANEOUS
→ Push to actuate The door will open automatically when it is slid open manually
approx. 3 mm from the closed position.
▪ This function is not active on a locked door and in the
operating modes
‘One-Way’
and
‘Manual mode’
.
▪ If a brake is set, it may not be applied in the closed
position.
→ Disabled X Function disabled
→ Normal The drive will only respond to short-term acceleration of the
door leaf and not to slow movement through pressure building
up (e.g. wind).
→ Slow Reaction as above, but slower opening of the door.
→ Manual mode with sen-
sors
All sensors are also active in ‘Manual mode’.
NOTICE
For the correct function of ‘Manual mode with sensors’, the corresponding pa-
rameters must be set and the BDE-D or the toggle switch must be switched on
“Manual’.
NOTICE
In ‘Manual mode with sensors’ the door can be opened manually by non-disabled
people; disabled people, however, disabled persons may trigger an automatic
opening of the door by remote control.
Menu: Manual mode / Active sensors / SIS disabled or SIS enabled
Do not enable ‘Assisted closure’