DRILL INCOMING WIRE ACCESS
HOLE ANYWHERE IN THIS AREA
(OPPOSITE TO HINGE SIDE)
KNOCK OUT TABS ARE
PROVIDED IN END CAPS
FOR INCOMING POWER
WIRE AND/OR SWITCH
HINGE SIDE
ENSURE MOTOR HARNESS
WILL REACH CONTROL BOARD
WHEN PLACED IN THIS LOCATION
STRIKE SIDE
INSTALLATION OF L-16 CONNECTOR
FOR ARMOURED (BX) CABLE/ INCOMING
POWER (TO SECURE LINE TO HEADER)
IS RECOMMENDED
TYPICAL THROUGH-HOLE INSTALLATION
UPPER HEADER ANCHORING HOLES
INCOMING POWER WIRE HOLE
(TYPICALLY LATCH SIDE)
DOOR FRAME
HEADER ANCHORING HOLES
MOUNTING HOLES CAN
ALSO BE PLACED ON
END CAPS DEPENDING ON
SITE CONDITIONS
A
A
SECTION A-A: SIDE VIEW
Holes can be made anywhere in header to secure.
All holes must be drilled into substantial support (studs, blocks, framing, etc.)
This may not reflect your installation.