4.4 Spring Tension Adjustment
This is useful for windy locations, and other areas where the door may need more force during the closing phase.
To begin,
• Remove the operator from the header.
• Remove the fender washer and machine screw at the end of the spindle.
• Detach the operator arm and remove the other two machine screws holding the operator to the header.
• You may now remove the operator, placing on secure flat surface on its side.
Method 1: Adjusting Spline Stop Position
STEP 1 - Loosen Stopper
Loosen the socket cap screw that keeps the spline stop anchored in place.
RH operator orientation
adjustment are shown.
For LH operator, please
reverse the images.
LOOSEN #10-32 x 1-1/4"
SOCKET CAP SCREW SPLINE STOP
(STOPPER)
#5/16"-18
HEX JAM NUT
ZINC PLATED
#5/16"-18x3/4"
LOW HEAD
SOCKET CAP SCREW
USE Record ARM
PROVIDED
Pg. 40