4.4 Spring Tension Adjustment
This is useful for windy locations, and other areas where the door may need more force during the closing phase.
To begin,
Remove the operator from the header.
Remove the fender washer and machine screw at the end of the spindle.
Detach the operator arm and remove the other two machine screws holding the operator to the header.
You may now remove the operator, placing on secure flat surface on its side.
Method 1: Adjusting Spline Stop Position
STEP 1 - Loosen Stopper
Loosen the socket cap screw that keeps the spline stop anchored in place.
RH operator orientation
adjustment are shown.
For LH operator, please
reverse the images.
LOOSEN #10-32 x 1-1/4"
SOCKET CAP SCREW SPLINE STOP
(STOPPER)
#5/16"-18
HEX JAM NUT
ZINC PLATED
#5/16"-18x3/4"
LOW HEAD
SOCKET CAP SCREW
USE Record ARM
PROVIDED
4.0 OPERATOR TUNING