EasyManua.ls Logo

REMBE Q-FlapCompact II - Pressure Loss and Explosion Class Data

REMBE Q-FlapCompact II
91 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
page 8 of 91 USB-QFLCII-14804/0
Unit
Q-FlapCompact II / Q-FlapCompact II plus series /
DN
160
200
250
280
315
355
400
Installed length
470
530
590
630
660
730
750
18.50
20.87
23.23
24.80
25.98
28.74
29.53
Width
400
440
490
520
570
630
680
15.75
17.32
19.29
20.47
22.44
24.80
26.77
Height
580
610
660
690
740
790
830
22.83
24.02
25.98
27.17
29.13
31.10
32.68
Inspection lid range
420
460
480
520
540
590
645
16.54
18.11
18.90
20.47
21.26
23.23
25.39
Bolt circle diameter
200
241
292
332
366
405
448
7.87
9.49
11.50
13.07
14.41
15.94
17.64
Bolt size
M10
M10
M10
M10
M10
M10
M10
Bolt length
30
30
30
35
35
35
35
1.18
1.18
1.18
1.38
1.38
1.38
1.38
Number of bolts
8
8
8
8
8
8
12
Maximum opening
angle of the flap
blade
20° 20° 20° 20° 20° 20° 30° 30°
Weight
41
46
55
60
69
89
99
90.39
101.41
121.25
132.28
152.12
196.21
218.26
Pressure loss at
20 m/s
Pa 400 ~400 ~400 320 ~330 340 ~370 ~400
Maximum reduced
excess pressure in
the enclosure (filter)
Bar 0.7 0.7 0.7 0.7 0.7 0.7 0.5 0.5
Pressure shock
resistance of the
inlet isolation device
Bar 1.5 0.95 0.95 0.95 0.95 0.95 0.6 0.6
Design available for
dust explosion class
St1
X X X X X X X X
Design available for
dust explosion class
St1 aluminum dust
(no heating value
restriction)
X X X X X X - -
Design available for
dust explosion class
St2
X X X X X X - -
Technical data
for size
DN 140 (5.51’’) to
DN 400 (15.75’’)

Table of Contents

Related product manuals