page 1 of 91 USB-QFLCII-14804/0
Translation of the original instruction
Operating and Maintenance Instruction Manual
Q-FlapCompact II/Q-Flap Compact II Plus
Inlet Isolation Device

Table of Contents

Question and Answer IconNeed help?

Do you have a question about the REMBE Q-FlapCompact II and is the answer not in the manual?

Summary

EC Declaration of Conformity

ATEX Compliance for Explosion Protection

Details ATEX directive compliance for explosion protection in endangered areas.

Applied Harmonized Standards

Lists harmonized standards and technical specifications applied to the device.

Technical Data Overview

Device Dimensions and Weight

Provides physical dimensions like width, height, length, and device weight.

Pressure Loss and Explosion Class Data

Specifies pressure loss values and availability for dust explosion classes.

General Information

Manual Icons and Symbols

Explains the meaning of various icons used for warnings and information.

Intended Use and Application Scope

Defines the intended purpose and application scope of the inlet isolation device.

Personnel Qualification Requirements

Details the necessary qualifications for personnel operating and servicing the device.

Product Warranty Information

Outlines the warranty terms, conditions, and exclusions for the product.

Safety Guidelines and Hazards

General Safety Warnings and Notices

Covers general warnings, device labels, and health hazards.

Operational and Environmental Hazards

Addresses crushing, electrical, fire, explosion, and environmental hazards.

Assembly, Operation, and Maintenance Safety

Safety instructions for assembly, operation, maintenance, and monitoring.

Functional Description

Q-FlapCompact II;Plus Overview

Provides an overview of the functional aspects of the Q-FlapCompact II/Plus device.

Inspection Lid and Locking Mechanism

Details the inspection lid and the locking mechanism's components and function.

Closed-Position Sensor Operation

Details the closed-position sensor, its function, and monitoring during system shutdown.

Additional Monitoring Features

Wear and Tear Sensor Functionality

Describes the wear and tear sensor, its function, and inspection needs.

Optional Level Sensor and Requirements

Explains the optional level sensor for detecting deposits and monitoring panel requirements.

Transport and Storage

Transport and Handling Instructions

Instructions for transporting the inlet isolation device, including checking for damage.

Storage Guidelines

Guidelines for storing the device in a dry, condensation-free environment.

Assembly and Commissioning Procedures

Installation Location and Conditions

Specifies requirements for installation location and general conditions.

Mounting Distances and Wiring

Provides installation dimensions, measures, and terminal box wiring diagram.

Commissioning Steps

Lists checks for initial commissioning and procedures after system start-up.

Operation and Maintenance

Pre-Start Up Checks and Valve Operation

Specifies checks before start-up and describes normal valve operation.

Inspection and Maintenance Plan

Outlines the inspection and maintenance schedule and safety precautions.

Maintenance Procedures

Details safe shutdown, lid operations, wear inspection, and mechanism checks.

Optional Sensor Maintenance

Level Sensor Inspection and Adjustment

Instructions for inspecting and adjusting the optional level sensor for dust detection.

Spare Parts and External Documentation

Spare Parts Identification and Ordering

Lists key spare parts and provides information on how to order them.

Technical Data for Related Components

References external documents for technical data on related components.

Technical Data Sheets

Switch Amplifier Technical Data

Detailed technical specifications for the switch amplifier.

Shotbolt Lock Unit Technical Data

Detailed technical specifications for the shotbolt lock unit.

Closed-Position Sensor Technical Data

Detailed technical specifications for the closed-position sensor.

Level Sensor KI505 A Technical Data

Detailed technical specifications for the optional level sensor KI505A.

Level Sensor KI505 A Operating Instructions

Operating instructions for the optional level sensor KI505A.

Annex

Q-FlapCompact II;Plus Operation Sequence

Describes the operational sequence and alarms with the monitoring panel.

REMBE Q-FlapCompact II Specifications

General IconGeneral
BrandREMBE
ModelQ-FlapCompact II
CategoryIndustrial Equipment
LanguageEnglish