EasyManuals Logo

Renesas R8C/20 User Manual

Renesas R8C/20
501 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #147 background imageLoading...
Page #147 background image
R8C/20 Group, R8C/21 Group 14. Timers
Rev.2.00 Aug 27, 2008 Page 131 of 458
REJ09B0250-0200
Figure 14.9 TRAIOC Register in Pulse Width Measurement Mode
Timer RA I/O Control Register
Symbol Address After Reset
TRAIOC
0101h 00h
Bit Symbol Bit Name Function RW
INT1
_
____
/TRAIO select bit 0 : INT1
_
____
/TRAIO pin (P1_7)
1 : INT1
_
____
/TRAIO pin (P1_5)
NOTE:
1.
RW
RW
When the same value from the TRAIO pin is sampled three times continuously, the input is determined.
b3 b2
TIOSEL
b1 b0
0 : TRAIO input starts at “L”
1 : TRAIO input starts at “H
0
b7 b6 b5 b4
TOPCR RW
TOENA RW
RW
TIPF0
TRAIO output control bit
0
TEDGSEL RW
TRAIO polarity sw itch bit
TIPF1
(b7-b6)
Nothing is assigned. If necessary, set to 0.
When read, the content is 0.
TRAO output enable bit
TRAIO input filter select
bits
(1)
b5 b4
0 0 : No filter
0 1 : Filter w ith f1 sampling
1 0 : Filter w ith f8 sampling
1 1 : Filter w ith f32 sampling
Set to 0 in pulse w idth measurement mode

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Renesas R8C/20 and is the answer not in the manual?

Renesas R8C/20 Specifications

General IconGeneral
BrandRenesas
ModelR8C/20
CategoryControl Unit
LanguageEnglish

Related product manuals