14 June, 2002 BIT SWITCHES
5-51
Service
Tables
Communication Switch 16
No FUNCTION COMMENTS
0 Not used Do not change the factory settings.
1 Optional G3 unit
0: Not installed
1: Installed
1: Change this bit to 1 when installing the optional
G3 unit.
2 Optional G4 unit
0: Not installed
1: Installed
1: Change this bit to 1 when installing the optional
G4 unit.
3-4 Not used Do not change the factory settings.
5 Use of PSTN-2 line
0: Tx or Rx
1: Rx only
Change this bit to 1 when the customer requires.
Also see system switch 18.
6 ISDN-G3 reception
0: Enabled
1: Disabled
Change this setting when the customer requires.
7 ISDN dual communication
0: Enabled
1: Disabled
1: The machine uses only one B channel for
communication. This enables a customer to occupy
another B channel for other purposes such as an
internet communication.
Communication Switch 17
No FUNCTION COMMENTS
0 SEP (selective polling) reception
0: Disabled 1: Enabled
0: Disables features that require SEP (selective
polling) signal reception.
1 SUB reception
0: Disabled 1: Enabled
0: Disables features (such as confidential
reception to another maker’s machine) that require
SUB (Sub-address) signal reception.
2 PWD (Password) / SID (Sender
ID) reception
0: Disabled 1: Enabled
0: Disables features that require PWD or SID
signal reception.
3-6 Not used Do not change the settings.
7 Action when there is no box with
an F-code that matches the
received SUB code
0: Disconnect the line
1: Receive the message (using
normal reception mode)
Change this setting when the customer requires.

Table of Contents