INSTALLING OPTIONAL UNITS 14 June, 2002
1-18
1.3.7 COUNTER TYPE 510
1. Remove the top cover [A] (2 screws)
and right cover [B] (5 screws).
2. Cut away the small cover [C].
3. Attach the counter [D] on the machine,
then connect relay harness [E] (contained
in the kit) to the counter harness.
4. Connect the relay harness [E] to CN52 on
the FCU board, then clamp the harness.
5. Replace the top and the right covers.
6. Make some copies and check whether or
not the counter is working correctly. If it is
not, check the connection of the FCU-
counter harness.
H230I003.WMF