NCU PARAMETERS 14 June, 2002
5-78
Address Function Unit Remarks
401F12 PSTN detection time for the silent
period after ring-back tone detected
(high)
20 ms
401F13 PSTN busy tone frequency upper
limit (high byte)
401F14 PSTN busy tone frequency upper
limit (low byte)
Hz
(BCD)
If both addresses contain
FF(H), tone detection is
disabled.
401F15 PSTN busy tone frequency lower
limit (high byte)
401F16 PSTN busy tone frequency lower
limit (low byte)
Hz
(BCD)
If both addresses contain
FF(H), tone detection is
disabled.
401F17 PABX dial tone frequency range
(high byte)
401F18 PABX dial tone frequency range (low
byte)
Hz
(BCD)
If both addresses contain
FF(H), tone detection is
disabled.
401F19 PABX dial tone frequency lower limit
(high byte)
401F1A PABX dial tone frequency lower limit
(low byte)
Hz
(BCD)
If both addresses contain
FF(H), tone detection is
disabled.
401F1B PABX dial tone detection time
401F1C PABX dial tone reset time (low)
401F1D PABX dial tone reset time (high)
401F1E PABX dial tone continuous tone time
401F1F PABX dial tone permissible drop time
If 401F1B contains FF, the
machine pauses for the
pause time (401F20 /
401F21).
401F20 PABX wait interval (high)
401F21 PABX wait interval (low)
20 ms
401F22 PABX ring-back tone detection time 20 ms
401F23 PABX ring-back tone off detection
time
20 ms
If both addresses contain
FF(H), tone detection is
disabled.
401F24 PABX detection time for the silent
period after ring-back tone detected
(low)
20 ms If both addresses contain
FF(H), tone detection is
disabled.
401F25 PABX detection time for the silent
period after ring-back tone detected
(high)
20 ms If both addresses contain
FF(H), tone detection is
disabled.
401F26 PABX busy tone frequency upper
(high byte)
401F27 PABX busy tone frequency lower
(low byte)
Hz
(BCD)
If both addresses contain
FF(H), tone detection is
disabled.
401F28 PABX busy tone frequency lower
(high byte)
401F29 PABX busy tone frequency lower
(low byte)
Hz
(BCD)
If both addresses contain
FF(H), tone detection is
disabled.
401F2A Busy tone ON time: range 1 20 ms
401F2B Busy tone OFF time: range 1
401F2C Busy tone ON time: range 2
401F2D Busy tone OFF time: range 2
401F2E Busy tone ON time: range 3
401F2F Busy tone OFF time: range 3
401F30 Busy tone ON time: range 4