System Service Mode
SM Appendix 9-15 D037/D038/D040/D041
Appendix:
SP Mode
Tables
Center Temp. 1: 226– ENG
[-10 / 10 / 0 / 1 deg/step]
010
Specifies the temperature correction for the heating roller (center) when the
paper width is 226 mm or more.
The start time of this SP can be adjusted with SP1116-018.
Ends Temp. 1: 226– ENG
[-10 to 10 / 0 / 1 deg/step]
011
Specifies the temperature correction for the heating roller (ends) when the
paper width is 226 mm or more.
The start time of this SP can be adjusted with SP1116-018.
Center Temp. 2: 226– ENG
[-10 to 10 / 0 / 1 deg/step]
012
Specifies the temperature correction for the heating roller (center) when the
paper width is 226 mm or more.
The start time of this SP can be adjusted with SP1116-019.
Ends Temp. 2: 226– ENG
[-10 to 10 / 0 / 1 deg/step]
013
Specifies the temperature correction for the heating roller (ends) when the
paper width is 226 mm or more.
The start time of this SP can be adjusted with SP1116-019.
Center Temp. 3: –226 ENG
[-10 to 10 / 0 / 1 deg/step]
014
Specifies the temperature correction for the heating roller (center) when the
paper width is less than 226 mm.
The start time of this SP can be adjusted with SP1116-020.
Ends Temp. 3: –226 ENG
[-10 to 10 / -5 / 1 deg/step]
015
Specifies the temperature correction for the heating roller (ends) when the
paper width is less than 226 mm.
The start time of this SP can be adjusted with SP1116-020.
Center Temp. 4: –226 ENG
[-10 to 10 / 0 / 1 deg/step]
016
Specifies the temperature correction for the heating roller (center) when the
paper width is less than 226 mm.
The start time of this SP can be adjusted with SP1116-021.