System Service Mode
D037/D038/D040/D041 9-16 SM Appendix
Ends Temp. 4: –226 ENG
[-10 to 10 / -10 / 1 deg/step]
017
Specifies the temperature correction for the heating roller (ends) when the
paper width is less than 226 mm.
The start time of this SP can be adjusted with SP1116-021.
Control Time 1: 226– ENG
[0 to 250 / 0 / 1 sec/step]
018
Specifies the start time of the temperature correction that is set with
SP1116-010 and -011.
The temperature correction is added when the time specified with this SP has
passed after feeding the paper.
Control Time 2: 226– ENG
[0 to 250 / 0 / 1 sec/step]
019
Specifies the start time of the temperature correction that is set with
SP1116-012 and -013.
The temperature correction is added when the time specified with this SP has
passed after feeding the paper.
Control Time 3: –226 ENG
[0 to 250 / 30 / 1 sec/step]
020
Specifies the start time of the temperature correction that is set with
SP1116-014 and -015.
The temperature correction is added when the time specified with this SP has
passed after feeding the paper.
Control Time 4: –226 ENG
[0 to 250 / 60 / 1 sec/step]
021
Specifies the start time of the temperature correction that is set with
SP1116-016 and -017.
The temperature correction is added when the time specified with this SP has
passed after feeding the paper.
022 Center Temp.1:Duplex:226- ENG
023 Ends Temp.1:Duplex:226- ENG
024 Center Temp.2:Duplex:226- ENG
025 Ends Temp.2:Duplex:226- ENG
[-10 to 10 / 0 / 1 deg/step]