Code Meaning Suggested Cause/Action
MPh that was not available in
the currently selected symbol
rate.
0-87
The control channel started after
an unsuccessful primary
channel.
• The receiving terminal restarted the control channel
because data reception in the primary channel was
not successful.
• This does not result in an error communication.
0-88
The line was disconnected
because PPR was transmitted/
received 9 (default) times within
the same ECM frame.
• Try using a lower data rate at the start.
• Try adjusting the cable equalizer setting.
2-11
Only one V.21 connection flag
was received
• Replace the FCU.
2-12 Modem clock irregularity • Replace the FCU.
2-13 Modem initialization error
• Turn off the machine, then turn it back on.
• Update the modem ROM.
• Replace the FCU.
2-23
JBIG compression or
reconstruction error
• Turn off the machine, then turn it back on.
2-24 JBIG ASIC error • Turn off the machine, then turn it back on.
2-25
JBIG data reconstruction error
(BIH error)
• JBIG data error
• Check the sender’s JBIG function.
• Update the MBU ROM.
2-26
JBIG data reconstruction error
(Float marker error)
2-27
JBIG data reconstruction error
(End marker error)
2-28
JBIG data reconstruction error
(Timeout)
2-29 JBIG trailing edge maker error
• FCU defective
• Check the destination device.
Error Codes