Bit 7: 0, Bit 6: 1 = inch
Bit 7: 1, Bit 6: 0 = mm and inch
(default)
Bit 7: 1, Bit 6: 1 = Not used
The setting determined by these bits is informed to the
transmitting terminal in the pre-message protocol exchange
(in the DIS/NSF frames).
Communication Switch 15 – Not used (do not change the settings)
Communication Switch 16 – Not used (do not change the settings)
Communication Switch 17 – Not used (do not change the settings)
Communication Switch 18 - Not used (do not change the settings)
Communication Switch 19 - Not used (do not change the settings)
Communication Switch 1A - Not used (do not change the settings)
Communication Switch 1B [SP No. 1-104-028]
No FUNCTION COMMENTS
0-7
Extension access code (0 to 7) to
turn V.8 protocol On/Off
0: On
1: Off
If the PABX does not support V.8/V.34 protocol procedure,
set this bit to “1” to disable V.8.
Example: If “0” is the PSTN access code, set bit 0 to 1.
When the machine detects “0” as the first dialed number,
it automatically disables V.8 protocol. (Alternatively, if “3”
is the PSTN access code, set bit 3 to 1.)
Communication Switch 1C [SP No. 1-104-029]
No FUNCTION COMMENTS
0-1
Extension access code (8 and 9) to
turn V.8 protocol On/Off
0: On
1: Off
Refer to communication switch 1B.
Example: If “8” is the PSTN access code, set bit 0 to 1.
When the machine detects “8” as the first dialed number,
it automatically disables V.8 protocol. (If “9” is the PSTN
access code, use bit 1.)
2-7 Not used Do not change the settings.
Communication Switch 1D - Not used (do not change the settings)
Communication Switch 1E - Not used (do not change the settings)