2.5 SERVICE PROGRAM MODE TABLE
1. In the
Function
column, comments (extra information) are in italics.
2. In the
Settings
column, the default value is printed in bold letters.
3. If there is a mark in the Mode No. column, copies can be made within
this SP Mode.
Mode No. Function Settings
4
Forced Start
(Free Run)
Performs a free run with a forced start.
Press the
key to start the free tun.
Press the
key to stop the free run.
If this mode is switched on, the copier starts the free
run even if the fusing temperature has not reached
the required value yet.
This mode is performed with the selected paper size
and magnification ratio without the paper feed clutch
or total counter increment.
Normally, use SP7 to prevent fusing-related
service call conditions from occurring.
5
Free Run with
Exposure
Lamp Off
A free run is performed without exposure.
Press the
key to start the free run.
Press the
key to stop the free run.
This mode is performed with the selected paper size
and magnification ratio without the paper feed clutch
or total counter increment.
Normally, use SP7 to reduce the cleaning blade
load.
6
Misfeed
Detection Off
Copies are made without misfeed detection by the
registration, exit sensors, and sorter paper sensor.
Press the
key to make a copy. It stops when
reaching the set count, or when the
key is
pressed.
Use this mode to check whether a paper misfeed
was caused by a sensor malfunction.
The total counter increments when copies are
made in this mode.
7
Free Run Performs a free run with the exposure lamp on.
Press the
key to start the free run.
Press the
key to stop the free run.
This mode is performed with the selected paper size
and magnification ratio without the paper feed clutch
or total counter increment.
Before starting, close the platen cover to reduce
the cleaning blade load.
PROGRAM MODES 20 December 1996
4-10

Table of Contents