1. INSTALLATION REQUIREMENTS
1.1 ENVIRONMENT
1. Temperature Range: 10°C to 30°C (50°F to 87°F)
2. Humidity Range: 15% to 90% RH
3. Ambient Illumination: Less than 1,500 lux (Do not exposure to direct
sunlight.)
4. Ventilation: Room air should turn over at least 3 times per
hour
5. Ambient Dust: Less than 0.15 mg/m
3
(4 x 10
-3
oz/yd
3
)
6. If the place of installation is air-conditioned or heated, do not place the
machine:
1) Where it will not be subjected to sudden temperature changes.
2) Where it will not be directly exposed to cool air from an air-conditioner.
3) Where it will not be directly exposed to heat from a heater.
7. Do not place the machine where it will be exposed to corrosive gasses.
8. Do not install the machine at any location over 2,000 m (6,500 feet)
above sea level.
9. Place the copier on a strong and level base.
10. Do not place the machine where it may be subjected to strong vibrations.
1.2 MACHINE LEVEL
1. Front to back: Within 5 mm (0.2") of level
2. Right to left: Within 5 mm (0.2") of level
Installation
20 December 1996 INSTALLATION REQUIREMENTS
3-1