3. AROUND THE DRUM
3.1 IMAGING UNIT REMOVAL AND TONER BOTTLE
REMOVAL
 
  1. Open the front cover.
  2. Raise the toner bottle holder lever [A] as shown.
  3. Then push down the securing lever [B], and remove the toner bottle holder [C].
  4. Turn the "B1" lever [D] counterclockwise to lower the transfer corona unit.
  5. Remove the transfer corona unit or cover it with a clean sheet of paper.
  6. Remove the knob screw [E] and place a sheet of paper under the
imaging unit. Gently pull out the imaging unit [F]. Then place it on a clean
sheet of paper.
[B]
[C]
[A]
A219R516.wmf
[E]
[D]
[F]
A219R517.wmf
AROUND THE DRUM 20 December 1996
6-18