3. PRACTICAL SP MODE USE TABLE
The following table shows the SP modes that must be done, and the order in
which they must be done when the listed items are replaced or cleaned.
No.
SP
Mode
No.
Description
Replaced or Cleaned Item
Developer TD Sensor OPC Drum
ADS
Sensor
Optics
(Scanner
Unit)
1 SP66
TD Sensor
Initial
Setting
❍❍
2 SP93
V
R
Correction
Reset
❍
*3 SP48
Light
Intensity
Adjustment
❍❍
4 SP56
ADS
Reference
Voltage
Adjustment
❍❍❍
*NOTE:
1) Before performing SP48 (Light Intensity Adjustment), always
check to see if the setting of SP33 (Image Bias Adjustment -
Manual ID Mode) is set to the default value so that it is possible to
adjust the light intensity properly.
2) The V
L
and V
L2
corrections are reset automatically when entering
this mode.
(Priority Number)
PRACTICAL SP MODE USE TABLE 20 December 1996
4-26