4. BLOWN FUSE CONDITIONS
FUSE
Rating Symptom when turning
on the Main Switch
120 V 230 V
AC Drive/DC Power Supply Board
F1 15 A/125 V T6.3 A/250 V No response
F2 8 A/125 V T6.3 A/250 V E2B is displayed
F3 3.15 A/125 V T3.15 A/250 V No response
F4 5 A/125 V T3.15 A/250 V No response
5. USER CODES
U - code Contents
U1 Right vertical guide opened
U2 Key counter not set (JP101 is cut)
U4 Optional sorter not set
U6 Developer not installed
USER CODES
Trouble-
shooting
20 December 1996 BLOWN FUSE CONDITIONS
7-31